DataCentreFinderTHE UK INFRASTRUCTURE DIRECTORY

VeloxServ Communications Ltd

VeloxServ Velox1

Wolverhampton · West Midlands · England · United Kingdom

Velox1 forms part of VeloxServ’s Wolverhampton colocation offering, with resilient power, carrier neutral connectivity and flexible rack products described across the shared site.

  • 24/7 remote hands
  • Carrier neutral
Facility photography has not yet been supplied.

THE FACILITY AT A GLANCE

About this data centre

Carrier neutral colocation within VeloxServ's Wolverhampton campus.

Velox1 is one of two VeloxServ Communications Ltd colocation facilities marketed at Merryhills Enterprise Park, Park Lane, Wolverhampton, alongside Velox2. VeloxServ's own website and PeeringDB list both as separate data centres at the same address and coordinates, so public sources cannot currently confirm whether they are physically separate buildings or halls within the same site. The facility offers carrier neutral colocation with N+N power and cooling redundancy and a published PUE of 1.3.

Services & suitable workloads

  • Colocation
  • High density hosting
  • Network services
Facility type
Colocation

SPACE FOR YOUR DEPLOYMENT

Racks & specifications

Rack formats and availability recorded for this facility. Confirm your requirements with the operator.

Rack options

Individual U space

Size / capacity: 1U to 4U

Available

Quarter rack

9U usable rack space

Available

Half rack

20U usable rack space

Available

Full rack

42U usable rack space

Available
Resilience
N+N UPS and generator design, published PUE of 1.3
Connectivity
Carrier neutral with Zayo, BT Openreach, Virgin Media and VeloxServ's own AS3170 network
Duplicate risk
Velox1 and Velox2 share the same published address and PeeringDB coordinate; physical separation is not independently confirmed
Operational support
24/7 remote hands
Trust classification
Formal Tier classification not evidenced
Rack capacity or formats
1U to 4U, quarter, half, full and high density options marketed

BUILT TO KEEP YOU RUNNING

Power & cooling

Power infrastructure

Total facility capacity
Not supplied
UPS configuration
N+N
Generator backup
Yes

Cooling systems

Cooling type
Not supplied
Cooling redundancy
N+1

Design Pue: 1.3

MAKE THE RIGHT CONNECTIONS

Connectivity

Reported carrier accessNot supplied
Carrier neutralYes
Exchange connections listedNone supplied

Carrier neutral with Zayo, BT Openreach and Virgin Media named

Individual carrier connections have not been supplied. A reported carrier total does not establish on-site presence.

Network capabilities

Meet-me room
Not supplied
Cross-connects
Not supplied
Dark fibre
Not supplied
Nearby internet exchange
Not supplied

PROTECTING YOUR INFRASTRUCTURE

Security

Physical security

  • CCTV
  • Controlled access
  • Fire suppression

24/7 monitored access with CCTV and ANPR cameras, proximity access control, VESDA smoke detection and FM200 fire suppression.

UNDERSTAND THE EVIDENCE

Compliance & standards

VeloxServ displays ISO 9001 and ISO 27001:2022 certification badges, with certificate documents published by the operator. These certificates are issued to VeloxServ Communications Ltd and do not distinguish between the Velox1 and Velox2 facilities, so facility specific scope is not independently confirmed.

A listed standard does not by itself confirm certification of this facility. Check the scope, evidence and validity with the operator.

GETTING THERE

Location & access

Merryhills Enterprise Park, Park Lane, Wolverhampton, WV10 9TJ
Get directions ↗ (opens in a new tab)

Site access

On-site parking
Not confirmed — check with the operator

YOUR QUESTIONS, ANSWERED

Frequently asked questions

Where is Velox1 located?
VeloxServ lists Velox1 at Merryhills Enterprise Park, Park Lane, Wolverhampton, WV10 9TJ.
Is Velox1 a separate building from Velox2?
Not confirmed. VeloxServ and PeeringDB both list Velox1 and Velox2 at the same address and coordinate, so public sources cannot confirm whether they are separate buildings or halls within the same site.
What power and cooling resilience does Velox1 have?
VeloxServ states N+N UPS and generator protection and a published PUE of 1.3.
Is Velox1 carrier neutral?
Yes. VeloxServ states the facility is carrier neutral with named connectivity from Zayo, BT Openreach and Virgin Media, plus its own AS3170 network.
What certifications does VeloxServ hold?
VeloxServ publishes ISO 9001 and ISO 27001:2022 certificates at company level. These do not distinguish between Velox1 and Velox2, so facility specific certification scope is not independently confirmed.

MAKE AN INFORMED DECISION

Facility assessment

Information suppliedLast reviewed

Deployment fit

Velox1 offers carrier neutral colocation at VeloxServ's Wolverhampton campus, with N+N power and cooling redundancy and named connectivity from Zayo, BT Openreach and Virgin Media. VeloxServ markets Velox1 and Velox2 as separate facilities, but both are listed at the same address and PeeringDB coordinate, so buyers should confirm directly with VeloxServ whether they are considering distinct buildings before ordering.

Sources & verification

Use this profile as a starting point. Confirm current availability, commercial terms and any required certification directly with VeloxServ Communications Ltd.