nLighten Leeds LBA1 (Normanton)

Leeds · Yorkshire and the Humber · England · United Kingdom

nLighten Leeds LBA1 is a carrier-neutral edge colocation data centre at White Rose Technology Centre, Normanton Industrial Estate, WF6 1TD, close to the M62.

Information supplied Listing reviewed
  • Free to use
  • Independent service
  • No obligation
Ask about pricing & availability

THE ESSENTIALS

The facility at a glance.

OVERVIEW

About this data centre

nLighten carrier-neutral edge colocation for Leeds (LBA1)

nLighten describes LBA1 as a high-availability, secure edge data centre serving Leeds, with 650 m² of dedicated colocation space and 3,600 kW of site capacity at end-state. The site is close to the M62, 15 minutes by car from Leeds station and 40 minutes from Leeds Bradford Airport, with office space and ample parking.

Each cabinet has independent A and B power feeds. Standard air-cooled density is 2–7 kW, up to 15 kW per cabinet, and high-density AI-ready deployments of 15 kW to 150+ kW are available on request. Cooling and humidity are designed to the ASHRAE A1 allowable category, with a design PUE of 1.29, and the site has a Tier III design target.

LBA1 is carrier neutral, with diverse fibre entry points and meet-me areas. Security includes dual-factor access control (PIN and biometrics), full-coverage CCTV and fire suppression in the data hall, backed by a 24/7 service desk, 24/7 NOC access and on-site services. nLighten states 100% carbon-free energy backed by Guarantees of Origin and power purchase agreements.

Services & suitable workloads

  • Colocation
  • Remote hands
  • High-density colocation

Racks & space

Find the right amount of space for your equipment.

Rack options

Published rack formats and availability
Rack formatConfiguration & compatibilityReported availability
High-density rack

High-density (AI-ready) cabinets of 15 kW to 150+ kW on request.

On request

nLighten offers cabinets in a pre-defined modular aisle and containment system. Standard air-cooled density is 2–7 kW, up to 15 kW per cabinet; high-density (AI-ready) cabinets of 15 kW to 150+ kW are available on request.

Technical specifications

Fire suppression
Fire suppression in the data hall
Total floor space
650 m² of dedicated colocation space
Site capacity (end-state)
3,600 kW
Design PUE
1.29
Tier
Tier III design target

Power & cooling

Check the power your deployment needs and the systems behind it.

Power options

Published power options and availability
Power optionConfiguration & compatibilityReported availability
2 kW+

Standard air-cooled density 2–7 kW, up to 15 kW per cabinet.

Available
5 kW+

Standard air-cooled density 2–7 kW, up to 15 kW per cabinet.

Available
10 kW+

Standard air-cooled density 2–7 kW, up to 15 kW per cabinet.

Available
15 kW+

High-density (AI-ready) 15 kW to 150+ kW on request.

On request
20 kW+

High-density (AI-ready) 15 kW to 150+ kW on request.

On request
30 kW+ / custom

High-density (AI-ready) 15 kW to 150+ kW on request.

On request

Power infrastructure

Power distribution redundancy
Independent A and B feeds to each cabinet

Cooling systems

Cooling type
Air cooling as standard; cooling and humidity designed to ASHRAE A1 allowable category

nLighten lists redundant power with independent A and B feeds to each cabinet, 3,600 kW site capacity at end-state, a design PUE of 1.29, standard density of 2–7 kW up to 15 kW per cabinet, and 15 kW to 150+ kW high-density on request.

Sustainability

nLighten lists a design PUE of 1.29, 100% carbon-free energy backed by Guarantees of Origin, power purchase agreements, a calculated Integrated Carbon-Free Energy (ICFEn) score, and a feasibility study for heat recovery to local heating networks.

Connectivity

Explore network choice and the connections available to your equipment.

Carrier neutralYes

nLighten describes LBA1 as carrier neutral with diverse fibre entry points and meet-me areas for rapid activation, and says customers can select from more than 65 carriers and partners across its European footprint.

Network capabilities

Meet-me room
Yes

Security

Review how access to the site and equipment is protected.

Physical security

  • Biometric access
  • Controlled access
  • CCTV
  • Fire suppression

Monitoring systems

  • 24/7 monitoring

nLighten lists dual-factor access control (PIN and biometrics), full-coverage CCTV, fire suppression in the data hall, and a 24/7 service desk with 24/7 NOC access.

Certifications & standards

Check listed standards, their scope and the evidence recorded.

Tier designationTier 3 aligned (not certified)

Compliance overview

nLighten states a Tier III design target (not certified). Facility certifications are not listed on the LBA1 page.

Operator’s tier statement

nLighten states a Tier III design target. No Uptime Institute certification is published.

Location & access

Plan visits, deliveries and access for your team.

White Rose Technology Centre, Don Pedro Avenue, Normanton Industrial Estate, Normanton, Leeds, WF6 1TD
Get directions ↗ (opens in a new tab)

Site access

nLighten says the site is close to the M62 motorway, 15 minutes by car from Leeds station and 40 minutes from Leeds Bradford Airport, with ample parking.

On-site parking
Available

Travel & local connections

Motorway

M62

nLighten: close to the M62 motorway.

Rail

Leeds station

nLighten: 15 minutes by car.

Airport

Leeds Bradford Airport

nLighten: 40 minutes.

YOUR QUESTIONS, ANSWERED

Frequently asked questions

Where is nLighten Leeds LBA1?

nLighten gives the address as White Rose Technology Centre, Don Pedro Ave, Normanton Industrial Estate, WF6 1TD Normanton, close to the M62.

How much space and power does LBA1 have?

nLighten lists 650 m² of colocation space and 3,600 kW of site capacity at end-state. Confirm current available capacity with nLighten.

What power density can LBA1 support?

Standard air-cooled density is 2–7 kW, up to 15 kW per cabinet. High-density (AI-ready) deployments of 15 kW to 150+ kW are available on request.

Is LBA1 carrier neutral?

Yes. nLighten describes it as carrier neutral, with diverse fibre entry points and meet-me areas.

Does nLighten claim a Tier rating?

nLighten states a Tier III design target. It does not publish an Uptime Institute certification for LBA1.

About this listing

These details help you assess the listing. Confirm current availability and suitability with the operator.

Status
Information supplied
Last reviewed

YOUR NEXT STEP

Does nLighten Leeds LBA1 (Normanton) fit your plans?

Our free, independent enquiry service helps you confirm pricing, availability and the requirements that matter to your deployment. No obligation to proceed.

Ask about pricing & availability ↗